Description

Twin-line control-air pressure reducing unit (drawing SNC-R-A00004-0). Each line: 3/2-way cut-off cock, filter set (25 µm element), pressure reducing valve (Tescom 44-1312-9122-298, ^DRTA), outlet gauge, safety valve lifting at 8.5 bar and check valve; a 2-way cut-off cock cross-connects the lines. Supply max 30 bar, outlet 1-10 bar (set 7 bar), flow 4000 Nl/min at 30 bar supply and 2000 Nl/min at 15 bar; 36 kg.

Also known as: snc-r-a00004-0, senaco pressure reducing unit, control air reducing unit

Specifications

mediumcompressed air
drawingSNC-R-A00004-0
ambient k273-353
filter um25
weight kg36
components{"filter_set":"Senaco AE 121 010 0","check_valve":"DK-Lok V33E-F-12R","safety_valve":"Lorch 13862","filter_element":"Pall Aerolith 10","pressure_gauge":"WIKA 213 53 050","cut_off_cock_3_2":"Legris 0469 13 21","cut_off_cock_2_way":"Legris 4902 15 21","pressure_reducing_valve":"Tescom 44-1312-9122-298"}
outlet max bar10
outlet min bar1
outlet set bar7
supply max bar30
safety valve bar8.5
flow nl min at 15 bar2000
flow nl min at 30 bar4000

Other makers in this equipment

Models from other manufacturers under the same equipment. Listed as neighbours, not checked as equivalents.

^DRNT Telegraph Logger Spares

ML-800 / ML-800-V telegraph logger spare parts — recording heads, thermal paper rolls, print mechanisms. Logs all engine…

^DRNJ Telegraph Transmitter / Receiver

MT-800-III / MT-800-V telegraph transmitter and receiver — handle assemblies, potentiometers, contact switches. Bridge a…

^DRNY Emergency Maneuvering Handle Assembly

Engine-side local emergency maneuvering control stand — handle, linkage, and direct-acting pneumatic valves for manual e…

^DRNN Display & HMI Module

LCD display panel, keypad assembly, and indicator light modules for M-800-V / M-800-VII control consoles. Bridge and eng…

^DRNH Governor Control Unit

MCG-301 / MCG-302 / MCG-402 electronic governor control unit (Part No. 87A109, ~11 kg). Microcomputer-controlled RPM reg…

Send enquiry

Send an enquiry to the manufacturer of ^DRXA Pressure Reducing Unit SNC-R-A00004-0. One broadcast per day.

0 / 5,000

Contribute or correct

Spotted a missing or incorrect entry? Let the maintainers know. Zulu Code is open under CC BY 4.0 — every correction strengthens the standard for the whole industry.

Code map

^D  R  X  A
 │  │  │  └── Model: Pressure Reducing Unit SNC-R-A00004-0
 │  │  └───── Make: Senaco
 │  └──────── Equipment: Remote Control and Pneumatic Manoeuvring Systems
 └─────────── System: Pneumatic