^CACC
HB 15T
Description
Zulu Code has not yet published a description for ^CACC. Contribute one.
Did you know
- Miura began producing auxiliary marine boilers in 1967. The HB series, including the HB 15T, is part of Miura's marine auxiliary boiler offerings.
- The HB 15T is a large capacity marine auxiliary boiler within Miura's product line, offering an actual evaporation rate of 15,000 kg/h. It sits among other HB models, which range from 2,500 to 18,000 kg/h in actual evaporation.
- The HB 15T is designed for energy efficiency, boasting a high boiler efficiency of 85-87%. Its compact design allows for more efficient use of space, and its simple water tube structure facilitates easy inspection, cleaning, and replacement of water tubes.
| Model | Actual Evaporation (kg/h) | Boiler Efficiency (%) | Fuel Type |
|---|---|---|---|
| HB 10T | 10,000 | 85-87 | Heavy oil (380cSt equivalent), Low-sulfur fuel oil, Diesel oil |
| HB 15T | 15,000 | 85-87 | Heavy oil (380cSt equivalent), Low-sulfur fuel oil, Diesel oil |
| HB 18T | 18,000 | 85-87 | Heavy oil (380cSt equivalent), Low-sulfur fuel oil, Diesel oil |
Engineering Knowledge
General engineering guidance only — it may contain errors. Always follow the equipment's own documentation and the judgement of a qualified engineer.
Boiler surface shows signs of burnt marks or gas leaks
Inspect the boiler surface for burnt marks, which indicate gas leaks. Address any identified leaks immediately.
Fuel oil or steam leaks are observed from piping or tubing
Inspect all fuel oil and steam piping and tubing for leaks. Repair or replace any leaking sections.
Observation port glass at the furnace manhole is not clear
Clean the observation port glass at the furnace manhole to ensure a clear view inside the furnace.
Boiler mounting foot pad is obstructed or not sliding freely
Check the condition of the boiler mounting foot pad for any obstructions. Ensure it can slide freely to accommodate thermal expansion. Confirm grease has been supplied to the boiler mounting foot annually.
Cracks or deformation are present at the expansion joint
Inspect the expansion joint for any cracks or deformation. Repair or replace the expansion joint as necessary.
Boiler water supply flow has increased compared to past operating data
Investigate the cause of increased boiler water supply flow. This may indicate a leak or other system inefficiency.
Abnormal sound or vibration from the FD Fan
Check the FD Fan for abnormal sound or vibration. Inspect the bearing box for oil leaks and ensure grease is supplied periodically to the fan motor and vane damper.
Abnormal sound or vibration from the FO Pump
Check the FO Pump for abnormal sound or vibration. Inspect for leakage from the pump casing and shaft end, and ensure grease is supplied periodically to the pump and motor. Verify quenching oil has been replaced periodically.
Abnormal sound or vibration from the Pilot Burner Pump
Check the Pilot Burner Pump for abnormal sound or vibration. Inspect for leakage from the pump casing and shaft end, and verify pump discharge pressure is normal when running.
Fuel oil or steam leaks from the FO Heater
Inspect the FO Heater for any leaks of fuel oil or steam. Repair or replace any leaking components.
Competitive Models
Sunrod HG-3 — an oil-fired marine auxiliary boiler with 3 t/h steam capacity for heating fuel, cargo, and accommodation …
Send enquiry
Send an enquiry to the manufacturer of ^CACC HB 15T. One broadcast per day.
Contribute or correct
Spotted a missing or incorrect entry? Let the maintainers know. Zulu Code is open under CC BY 4.0 — every correction strengthens the standard for the whole industry.
Code map
^C A C C │ │ │ └── Model: HB 15T │ │ └───── Make: Miura │ └──────── Equipment: Auxiliary Boiler └─────────── System: Boiler