^ZULU Code The Wikipedia of Ship Machinery
^Z S E M M

^CACC

HB 15T

Zulu Code Model

Description

Zulu Code has not yet published a description for ^CACC. Contribute one.

Did you know

ModelActual Evaporation (kg/h)Boiler Efficiency (%)Fuel Type
HB 10T10,00085-87Heavy oil (380cSt equivalent), Low-sulfur fuel oil, Diesel oil
HB 15T15,00085-87Heavy oil (380cSt equivalent), Low-sulfur fuel oil, Diesel oil
HB 18T18,00085-87Heavy oil (380cSt equivalent), Low-sulfur fuel oil, Diesel oil

Sources: miuraz.co.jp; miuraz.co.jp; vesmec.com

Engineering Knowledge

General engineering guidance only — it may contain errors. Always follow the equipment's own documentation and the judgement of a qualified engineer.

Boiler surface shows signs of burnt marks or gas leaks

Inspect the boiler surface for burnt marks, which indicate gas leaks. Address any identified leaks immediately.

Fuel oil or steam leaks are observed from piping or tubing

Inspect all fuel oil and steam piping and tubing for leaks. Repair or replace any leaking sections.

Observation port glass at the furnace manhole is not clear

Clean the observation port glass at the furnace manhole to ensure a clear view inside the furnace.

Boiler mounting foot pad is obstructed or not sliding freely

Check the condition of the boiler mounting foot pad for any obstructions. Ensure it can slide freely to accommodate thermal expansion. Confirm grease has been supplied to the boiler mounting foot annually.

Cracks or deformation are present at the expansion joint

Inspect the expansion joint for any cracks or deformation. Repair or replace the expansion joint as necessary.

Boiler water supply flow has increased compared to past operating data

Investigate the cause of increased boiler water supply flow. This may indicate a leak or other system inefficiency.

Abnormal sound or vibration from the FD Fan

Check the FD Fan for abnormal sound or vibration. Inspect the bearing box for oil leaks and ensure grease is supplied periodically to the fan motor and vane damper.

Abnormal sound or vibration from the FO Pump

Check the FO Pump for abnormal sound or vibration. Inspect for leakage from the pump casing and shaft end, and ensure grease is supplied periodically to the pump and motor. Verify quenching oil has been replaced periodically.

Abnormal sound or vibration from the Pilot Burner Pump

Check the Pilot Burner Pump for abnormal sound or vibration. Inspect for leakage from the pump casing and shaft end, and verify pump discharge pressure is normal when running.

Fuel oil or steam leaks from the FO Heater

Inspect the FO Heater for any leaks of fuel oil or steam. Repair or replace any leaking components.

Competitive Models

Similar models from other manufacturers — apple to apple.

^CAAK Aalborg Volta
^CADA HG-3

Sunrod HG-3 — an oil-fired marine auxiliary boiler with 3 t/h steam capacity for heating fuel, cargo, and accommodation …

^CAAI Aalborg MISSION OC
^CAAH Aalborg MISSION
^CAEA Hull no 2614

Send enquiry

Send an enquiry to the manufacturer of ^CACC HB 15T. One broadcast per day.

0 / 5,000

Contribute or correct

Spotted a missing or incorrect entry? Let the maintainers know. Zulu Code is open under CC BY 4.0 — every correction strengthens the standard for the whole industry.

Code map

^C  A  C  C
       ── Model: HB 15T
     ───── Make: Miura
   ──────── Equipment: Auxiliary Boiler